The technical data of the welding machine MIG 210 Syn from RED by Lorch provide a comprehensive overview of performance values, connections, and operating conditions. They serve as a basis for safe operation, correct application, as well as for service and maintenance purposes.
| Technical Data | Unit | RED MIG 210 Syn |
| MIG-MAG Welding | ||
| I2min – I2max I2min: Rated value of the minimum welding current I2max: Rated value of the maximum welding current |
A | 50 – 200 |
| U2min – U2max U2min: Minimum value of the standardised welding voltage U2max: Maximum value of the standardised welding voltage |
V | 16.5 – 24 |
| U0: Rated value of the open-circuit voltage | V | 54 |
| Power setting | stepless | |
| Characteristic curve | constant | |
| I2: Rated welding current at a duty cycle of 100 % and an ambient temperature of 40 °C | A | 77 |
| U2: Conventional welding voltage at a duty cycle of 100 % and an ambient temperature of 40 °C | V | 17,9 |
| I2: Rated welding current at a duty cycle of 60 % and an ambient temperature of 40 °C | A | 100 |
| U2: Conventional welding voltage at a duty cycle of 60 % and an ambient temperature of 40 °C | V | 19 |
| Duty cycle at welding current I2max and an ambient temperature of 40 °C | % | 15 |
| I1: Rated supply current at a duty cycle of 100% | A | 12.46 |
| I1: Rated supply current at a duty cycle of 60% | A | 17.4 |
| I1: Rated supply current at welding current I2max | A | 41.5 |
| I1eff: Maximum effective supply current | A | 16 |
| S1: Apparent power at a duty cycle of 100% | kVA | 2.87 |
| S1: Apparent power at a duty cycle of 60% | kVA | 4 |
| S1: Apparent power at welding current I2max | kVA | 9.55 |
| Wire feed speed | m/min | 0.8 – 14 |
| Diameter of weldable wire electrodes | mm | 0.6 – 1.0 |
| Type of weldable wire electrodes | Round solid and flux-cored wires for MIG-MAG welding | |
| TIG Welding | ||
| I2min – I2max I2min: Rated value of the minimum welding current I2max: Rated value of the maximum welding current |
A | 10 – 200 |
| U2min – U2max U2min: Minimum value of the standardised welding voltage U2max: Maximum value of the standardised welding voltage |
V | 10.4 – 18 |
| U0: Rated value of the open-circuit voltage | V | 54 |
| Power setting | stepless | |
| Characteristic curve | constant | |
| I2: Rated welding current at a duty cycle of 100% and an ambient temperature of 40 °C | A | 89 |
| U2: Conventional welding voltage at a duty cycle of 100 % and an ambient temperature of 40 °C | V | 13,6 |
| I2: Rated welding current at a duty cycle of 60% and an ambient temperature of 40 °C | A | 115 |
| U2: Conventional welding voltage at a duty cycle of 60 % and an ambient temperature of 40 °C | V | 14,6 |
| Duty cycle at welding current I2max and an ambient temperature of 40 °C | % | 20 |
| I1: Rated supply current at a duty cycle of 100% | A | 12.1 |
| I1: Rated supply current at a duty cycle of 60% | A | 16.2 |
| I1: Rated supply current at welding current I2max | A | 32 |
| I1eff: Maximum effective supply current | A | 14.3 |
| S1: Apparent power at a duty cycle of 100% | kVA | 2.78 |
| S1: Apparent power at a duty cycle of 60% | kVA | 3.73 |
| S1: Apparent power at welding current I2max | kVA | 7.36 |
| Diameter of weldable tungsten electrodes | 1.6 – 2.4 | |
| Electrode welding | ||
| I2min – I2max I2min: Rated value of the minimum welding current I2max: Rated value of the maximum welding current |
A | 10 – 160 |
| U2min – U2max U2min: Minimum value of the standardised welding voltage U2max: Maximum value of the standardised welding voltage |
V | 20.4 – 26.4 |
| U0: Rated value of the open-circuit voltage | V | 54 |
| Power setting | stepless | |
| Characteristic curve | constant | |
| I2: Rated welding current at a duty cycle of 100% and an ambient temperature of 40 °C | A | 72 |
| U2: Conventional welding voltage at a duty cycle of 100 % and an ambient temperature of 40 °C |
V | 22,9 |
| I2: Rated welding current at a duty cycle of 60% and an ambient temperature of 40 °C | A | 92 |
| U2: Conventional welding voltage at a duty cycle of 60 % and an ambient temperature of 40 °C | V | 23,7 |
| Duty cycle at welding current I2max and an ambient temperature of 40 °C | % | 20 |
| I1: Rated supply current at a duty cycle of 100% | A | 14 |
| I1: Rated supply current at a duty cycle of 60% | A | 18.4 |
| I1: Rated supply current at welding current I2max | A | 34.9 |
| I1eff: Maximum effective supply current | A | 15.6 |
| S1: Apparent power at a duty cycle of 100% | kVA | 3.22 |
| S1: Apparent power at a duty cycle of 60% | kVA | 4.23 |
| S1: Apparent power at welding current I2max | kVA | 8 |
| Diameter of weldable stick electrodes | mm | 1.6 – 4.0 |
| Information according to Ecodesign Regulation (EU) 2019/1784 | ||
| η: Efficiency at the rated value of the duty cycle at an ambient temperature of 40 °C and the highest output power (MIG-MAG) | % | ≥ 83 |
| Power consumption in no-load condition (MIG-MAG) | W | 40 |
| Power supply circuit | ||
| U1: Rated supply voltage | V | 230 |
| Positive supply voltage tolerance | % | 10 |
| Negative supply voltage tolerance | % | 10 |
| Number of phases | 1~ | |
| Rated supply frequency | Hz | 50 / 60 |
| I1max: Rated maximum supply current | A | 41,5 |
| Residual current circuit breaker | Type B+ (min. 30 mA) | |
| Mains fuse (slow-blow) | A | 16 |
| λ: Power factor at welding current I2max | 0.6 | |
| Zmax: Maximum permissible mains impedance | mΩ | 220 |
| Rsce: Short-circuit ratio | 350 | |
| Ssc: Short-circuit power | MW | 3,77 |
| Recommended generator power | kVA | 14,4 |
| Supply connection cable | mm² | 2.5 |
| Mains plug | CEE 7/4 (IEC 60083) | |
| Device | ||
| Suitable wire feed rollers | see spare parts list | |
| Weight of suitable wire spool | kg | 5 |
| Dimensions/type of suitable wire spool | D200 | |
| Protection class (IEC 60529) | IP21S | |
| Insulation class (IEC 60085) | H | |
| Cooling type (IEC 60076-2) | F | |
| Noise emission | dB(A) | <70 |
| Markings | S, CE | |
| Environmental conditions | ||
| Ambient air temperature range during operation | ° C (°F) | –10 ... +40 (+14 ... +104) |
| Ambient air temperature range during transport and storage | ° C (°F) | –25 ... +55 (–13 ... +131) |
| Relative humidity of the ambient air at 40 °C (104 °F) | % | ≤ 50 |
| Relative humidity of the ambient air at 20 °C (68 °F) | % | ≤ 90 |
| Dimensions and weights | ||
| Dimensions (LxWxH) | mm | 460 x 175 x 310 |
| Weight | kg | 10 |
| Standard equipment | ||
| Number of rollers in feed unit | wire feed rolls (2 of which are powered) | |
| Feed roll | mm | Steel 0.8 / 1.0 |
You can also find the technical data in the user manual in the download area.