A thermal overload on the RED MMA 160 PRO can occur if the welding machine is overused or the cooling is no longer sufficient. To prevent damage to the device, it switches off automatically. The device indicates excessively high temperatures by lighting up the thermometer symbol on the control panel. Below you will find possible causes and solutions.
Possible Causes and Solutions
Permissible duty cycle exceeded
Solution: Let the device cool down while idle.Airflow obstructed
Solution: Check air inlet and outlet on the device.Fan defective
Solution: Turn the device off and on. The fan should start briefly; replace if necessary.Ambient temperature too high
Solution: Check the ambient temperature.
Note:
An automatic shutdown due to thermal overload protects your device from permanent damage. Allow the device to cool down completely before continuing work. If the cause is not clearly identifiable or the fault persists, please contact us via the contact form.
An overview of all error and information messages can be found in the section Repair and Warranty
Detailed information on operation and further instructions on handling RED devices can be found in the user manual of your RED MMA 160 PRO welding machine