Here you will find an overview of possible causes and the appropriate solutions when your RED MIG 210 Syn displays the message E2 on the screen. This way, you can proceed step by step and get your device back into operation quickly.
The error code E2 on your MIG-MAG welding machine RED MIG 210 Syn indicates a thermal overload. The welding machine has switched off due to excessively high temperatures to prevent damage.
| Code | Fault | Possible Cause | Elimination |
| E2 | thermal overload | permissible duty cycle exceeded | Allow the device to cool down while idle |
| Airflow disrupted | Check air intake and exhaust on the device | ||
| Fan defective | Turn the device off and on; the fan should start briefly; replace if necessary | ||
| Ambient temperature too high | Check ambient temperature |
An overview of all error and information messages for the RED MIG 210 Syn can be found in this article: Troubleshooting (RED MIG 210 Syn)
Detailed information on operation and further advice on handling RED devices can be found in the MIG 210 SYN welding machine operation manual